VARIAN X-RAY TUBES | NDT
 

 

NDI-160/20

Maximum voltage 160kV  NDI-160/21
Target Angle 20 Degrees
Focal Spot Size D=1.0 mm
D=1.0 mm
Current 4mA@160kV
Inherent Filtration 1 mm BE
Download Datasheet
 

NDI-160/21

Maximum voltage 160kV  NDI-160/21
Target Angle 20 Degrees
Focal Spot Size D=1.0 mm
D=3.0 mm
Current 10mA@160kV
Inherent Filtration 1 mm BE
Download Datasheet
 

NDI-160/22

Maximum voltage 160kV  NDI-160/21
Target Angle 20 Degrees
Focal Spot Size D=1.0 mm
D=5.5 mm
Current 13mA@160kV
Inherent Filtration 1 mm BE
Download Datasheet
 

NDI-225/20

Maximum voltage 225kV  
Target Angle 20 Degrees
Focal Spot Size D=1.0 mm
D=1.0 mm
Current 2.5mA@225kV
Inherent Filtration 1 mm BE
Download Datasheet
 

NDI-225/21

Maximum voltage 225kV  NDI-225
Target Angle 20 Degrees
Focal Spot Size D=1.0 mm
D=3.0 mm
Current 7mA@225kV
Inherent Filtration 1 mm BE
Download Datasheet
 

 

NDI-225/22

 

Maximum voltage 225kV  
Target Angle 20 Degrees
Focal Spot Size D=1.0 mm
D=5.5 mm
Current 5.5mA@225kV
Inherent Filtration 1 mm BE
Download Datasheet

NDI-320/26

Maximum voltage 320kV  
Target Angle 20 Degrees
Focal Spot Size D=3.0 mm
D=5.5 mm
Current 13MA@320kV
Inherent Filtration 4 mm BE
Download Datasheet
 

NDI-320/23
 

Maximum voltage 320kV
Target Angle 20 Degrees
Focal Spot Size D=1.9 mm
D=3.6 mm
Current 5mA@320kV
Inherent Filtration 4 mm BE
Download Datasheet

NDI-321

Maximum voltage 320kV  
Target Angle 20 Degrees
Focal Spot Size D= 8.0 mm
Current 13mA@320kV
Inherent Filtration 4 mm BE
Download Datasheet
 

 

NDI-350/23

 

Maximum voltage 350kV
Target Angle 20 Degrees
Focal Spot Size D=1.9 mm
D=3.6 mm
Current 5mA@350kV
Inherent Filtration 4 mm BE
Download Datasheet


 

NDI-350/26

Maximum voltage 350kV
Target Angle 20 Degrees
Focal Spot Size D=3.0 mm
D=5.5 mm
Current 12mA@350kV
Inherent Filtration 4 mm BE
Download Datasheet
 

NDI-451

Maximum voltage 450kV
Target Angle 30 Degrees
Focal Spot Size D=2.5 mm
D=5.5 mm
Current 10mA@450kV
Inherent Filtration 2.3 mm Fe + 1mm Cu
Download Datasheet
 

NDI-452

Maximum voltage 450kV
Target Angle 30 Degrees
Focal Spot Size D=2.5 mm
D=5.5 mm
Current 10mA@450kV
Inherent Filtration 2.3 mm Fe + 1mm Cu
Download Datasheet

Questions regarding our X-Ray Support Services?
Questions

Our friendly and knowledgeable team of NDT technicians are standing by to answer any questions you may have regarding Willick Engineering's
X-Ray Solutions or any other industry related issues.

We welcome you to contact us toll free at
800-756-2626 or by using the form below to send an electronic message.  

 
First Name:*
Last Name:*
Email:*
Phone number
(+ area code):
Comment:
or Question
      


*All information collected is kept strictly private and will never be shared, sold, or used for solicitation.

 

NEW !

2009 Xplorer X-RAY sets 45KHZ software / hardware control panel or both.

 

 
 
digital