Reference X-ray tube Maximum nominal operating parameters Focal spot
size
Weight PDF
Voltage kV
Power W
EN 12543
mm
Monopolar Tubes > Monopolar Tubes > Monopolar Tubes >  
THX 100/1055
100
900
3000
1.0
5.5
6.5
THX 100/1030
100
900
2500
1.0
5.5
6.5
THX 100/0510
100
450
900
0.5
1.0
6.5
 
THX 160/G
160
-
4000
-
5.5x8.5
6.5
THX 160/1055
160
900
4000
1.0
5.5
6.5
THX 160/1030
160
900
2500
1.0
3.0
6.5
THX 160/0510
160
450
900
0.5
1.0
6.5
THX 1060/1010
160
900
900
1.0
1.0
6,5
 
THX 180
180
2700
3.0
21*
 
THX 225/WA
225
4000
5.5
12
THX 225/G
225
-
4000
-
5.5x8.5
THX 225/1055
225
900
4000
1.0
5.5
12
THX 225/1030
225
900
2500
1.0
3.0
12
THX 225/0510
225
450
900
0.5
1.0
12
 
MBE 161 / 5
160
640
1000
1.2
3.0
2.1
MBE 200
200
900
3.0
2.3
MBE 250
225
900
3.0
2.6
 
MBZ 300 / 1
300
on request
1.7
6.3
4.7
 
MB 350 / 1
350
1500
4200
3.0
6.3
4.8
MB 350 / 3
350
960
2250
1.9
3.6
4.8
MB 420 / 1
420
1500
4200
3.0
6.3
4.8
MB 420 / 3
420
960
2250
1.9
3.6
4.8
MB 450 / 1
450
1500
4500
3.0
6.3
4.8
MB 450 / 3
450
960
2250
1.9
3.6
4.8
MBWA 350/1
350
1500
3500
3.0
6.0
5.0
 
MBWA 420/1
420
1500
3500
3.0
6.0
5.0
 
MBWA 450/1
450
1500
3500
3.0
6.0
5.0
 
 
MB 450 / 1 H450C
450
1500
4500
3.0
6.3
97
MB 420 / 1 H450C
420
1500
4200
3.0
6.3
97
MB 350 / 1 H450C
350
1500
4200
3.0
6.3
97
MB 450 / 3 H450C
450
900
2250
1.9
3.6
97
MB 420 / 3 H450C
450
900
2250
1.9
3.6
97
MB 350 / 3 H450C
450
900
2250
1.9
3.6
97
MBWA 450 / 1 H450 WAB
450
1500
3500
3.0
6.0
97
 
MBWA 420 / 1 H450 WAB
420
1500
3500
3.0
6.0
97
 
 
MICROFOCUS tube and generator  
Hawkeye 130
THX 130 / 7-S
130
10
30
≤ 7 ?m
≤ 20 ?m
15

Questions regarding our X-Ray Support Services?
Questions

Our friendly and knowledgeable team of NDT technicians are standing by to answer any questions you may have regarding Willick Engineering's
X-Ray Solutions or any other industry related issues.

We welcome you to contact us toll free at
800-756-2626 or by using the form below to send an electronic message.  

 